Customer Support
Free shipping on all orders over $50 restrictions apply

HelpChemical Controller Probes (63 products)

Acu-Trol Chemical Probes

 ProductMeasuresCableOEMPrice
Acu-Trol pH Blue Sensor (No Wire)pHNone Yes$215.7517 in stock
Acu-Trol pH Blue Sensor with BNC to Wire and 10 Foot CablepH10 Ft. Yes$286.672 in stock
Acu-Trol ORP Red Sensor (No Wire)ORPNone Yes$215.743 in stock
Acu-Trol ORP Red Sensor with BNC to Wire and 10 Foot CableORP10 Ft. Yes$286.671 in stock
Acu-Trol ORP Red Sensor Gold Tip (No Wire)ORP - SaltNone Yes$299.01Usually ships in 7-10 days
Acu-trol Compatible pH Probe 744000260 - No Wire BNRpHNone No$104.684 in stock
Acu-trol Compatible ORP Probe 744000330 - No Wire BNRORPNone No$128.873 in stock
Acu-trol Compatible ORP Probe Gold Tip 744000390 - No Wire BNRORP - SaltNone No$144.47Usually ships in 3-5 days

BECSys Chemical Probes

 ProductMeasuresCableOEMPrice
BECSys Compatible pH Probe 9660010/9660013 - BNC Connector and 10 Foot CablepH10 Ft. No$111.74Usually ships in 5-7 days
BECSys Compatible ORP Probe 9660022/9660023 - BNC Connector and 10 Foot CableORP10 Ft. No$136.487 in stock
BECSys Compatible ORP Probe Gold Tip 9660038/9660040 - BNC Connector and 10 Foot CableORP - Salt Water10 Ft. No$152.12Usually ships in 5-7 days

CAT Controller Chemical Probes

 ProductMeasuresCableOEMPrice
CAT/Hayward PRO 25 ORP Probe with 2 Foot CableORP2 Ft. Yes$212.225 in stock
CAT Compatible ORP Electrode Probe Pro 25 - BNC Connector and 2.5 Foot CableORP2.5 Ft. No$127.706 in stock
CAT/Hayward PRO 25 ORP Probe with 10 Foot CableORP10 Ft. Yes$212.228 in stock
CAT Compatible ORP Electrode Probe Pro 25 - BNC Connector and 10 Foot CableORP10 Ft. No$127.702 in stock
CAT/Hayward PRO 25 ORP Gold Probe For Salt Water with 10 Foot CableORP - Salt10 Ft. Yes$213.662 in stock
CAT Compatible ORP Probe Pro 25 Gold Tip - BNC Connector and 10 Foot CableORP - Salt10 Ft. Yes$139.861 in stock
CAT/Hayward PRO 15 pH Probe with 10 Foot CablepH10 Ft. Yes$212.226 in stock
CAT/Hayward PRO 15 pH Probe with 2 Foot CablepH2 Ft. Yes$212.2220 in stock
CAT Compatible pH Probe Pro 15 - BNC Connector and 2.5 Foot CablepH2.5 Ft. No$102.364 in stock

Chemtrol Chemical Probes

 ProductMeasuresCableOEMPrice
Chemtrol ORP Probe with BCN Connector and 10 Foot CableORP10 Ft. Yes$281.156 in stock
Chemtrol ORP High Pressure Probe with BCN Connector and 10 Foot CordORP High Pressure10 Ft. Yes$427.20Usually ships in 5-7 days
Chemtrol pH Probe with BCN Connector and 10 Foot CablepH10 Ft. Yes$257.414 in stock
Chemtrol pH High Pressure Probe with BCN Connector and 10 Foot CablepH High Pressure10 Ft. Yes$404.67Usually ships in 5-7 days
Chemtrol Active Chlorine PPM Sensor - 0-002 ppm - Sea WaterChlorine (Active) PPM 0-002, Salt WaterNone Yes$1322.24Usually ships in 5-7 days
Chemtrol Active Chlorine PPM Sensor - 0-010 ppm - No WireChlorine (Active) PPM 0-010None Yes$1322.24Usually ships in 5-7 days
Chemtrol Active Chlorine PPM Sensor - 0-100 ppm - No WireChlorine (Active) PPM 0-100None Yes$1322.24Usually ships in 5-7 days
Chemtrol Active Chlorine PPM Sensor - 0-200 ppm - No WireChlorine (Active) PPM 0-200None Yes$1322.24Usually ships in 5-7 days
Chemtrol Bromine PPM Sensor - 0-010 ppm - No WireBromine PPM 0-010None Yes$1322.24Usually ships in 5-7 days
Chemtrol Free Chlorine PPM Sensor Upgrade Kit Complete - 0-10 ppmChlorine (Free) PPM 0-10None Yes$2333.48Usually ships in 5-7 days
Chemtrol Free Chlorine PPM Sensor - 0-002 ppm - No WireChlorine (Free) PPM 0-002None Yes$1322.24Usually ships in 5-7 days
Chemtrol Free Chlorine PPM Sensor - 0-10 ppm - No WireChlorine (Free) PPM 0-10None Yes$1336.28Usually ships in 2-3 days
Chemtrol Total Chlorine PPM Sensor - 0-002 ppm - No WireChlorine (Total) PPM 0-002None Yes$1322.24Usually ships in 5-7 days
Chemtrol Total Chlorine PPM Sensor - 0-010 ppm - No WireChlorine (Total) PPM 0-010None Yes$1322.24Usually ships in 5-7 days
Chemtrol Compatible ORP Sensor - BNC Connector and 10 Foot CableORP10 Ft. No$85.853 in stock
Chemtrol Compatible pH Sensor - BNC Connector and 10 Foot CablepH10 Ft. No$57.372 in stock

Hayward Chemical Probes

 ProductMeasuresCableOEMPrice
CAT/Hayward PRO 25 ORP Gold Probe For Salt Water with 2 Foot CableORP - Salt2 Ft. Yes$213.666 in stock
Hayward ORP Probe with 2 Foot CableORP2 Ft. Yes$214.627 in stock
Hayward pH Probe with 2 Foot CablepH2 Ft. Yes$212.221 in stock

Pentair Chemical Probes

 ProductMeasuresCableOEMPrice
Pentair pH Sensor for IntelliChem - No WirepHNone Yes$103.48Usually ships in 7-10 days
Pentair ORP Sensor for IntelliChem - No WireORPNone Yes$130.31Usually ships in 7-10 days
Pentair pH Sensor Cable - Blue BNC To Wire - 2 FeetpH2 Ft. Yes$47.30Usually ships in 7-10 days
Pentair ORP Sensor Cable - BNC To Wire - 2 FeetORP2 Ft. Yes$47.30Usually ships in 7-10 days

Polaris Chemical Probes

 ProductMeasuresThreadedCableOEMPrice
Polaris Compatible pH Probe Threaded 3-281 - BNC Connector and 10 Foot CablepHYes10 Ft. No$100.58Usually ships in 5-7 days
Polaris Compatible ORP Probe Threaded 3-271 - BNC Connector and 10 Foot CableORPYes10 Ft. No$124.82Usually ships in 5-7 days
Polaris Compatible ORP Probe Threaded Gold Tip 3-271 - BNC Connector and 10 Foot CableORP Salt WaterYes10 Ft. No$140.42Usually ships in 5-7 days
Polaris Compatible ORP Probe 3-270 - Standard BNC Connector and 2.5 Foot CableORPNo2.5 Ft. No$69.991 in stock
Polaris Compatible pH Probe 3-280 - Standard BNC Connector and 2.5 Foot CablepHNo2.5 Ft. No$49.995 in stock
Polaris Compatible ORP Sensor 3-270 - BNC Connector and 39 Inch CableORPNo3.25 Ft. No$90.80Usually ships in 5-7 days
Polaris Compatible pH Sensor 3-280 - BNC Connector and 39 Inch CablepHNo3.25 Ft. No$50.86Usually ships in 5-7 days

Pool Link Chemical Probes

Rola-Chem Chemical Probes

 ProductMeasuresCableOEMPrice
Rola-Chem pH Heavy-Duty Probe with 10 Foot CablepH10 Ft. No$150.52Usually ships in 2-3 days
Rola-Chem ORP Heavy-Duty Probe with 10 Foot CableORP10 Ft. No$153.645 in stock

Strantrol Chemical Probes

 ProductMeasuresCableOEMPrice
Strantrol Compatible pH Probe W2T4675 - BTD BNC Connector and 10 Foot CablepH10 Ft. No$228.964 in stock
Strantrol Compatible ORP Probe W2T3068 - BTD BNC Connector and 10 Foot CableORP10 Ft. No$253.237 in stock
Strantrol Compatible ORP Probe W2T3067 - BTD BNC Connector and 30 Inch CableORP3.25 Ft. No$249.1512 in stock
Strantrol Compatible pH Probe W2T4677 - BTD BNC Connector and 39 Inch CablepH3.25 Ft. No$221.528 in stock
Chemical Probe Help

Chemical Probe Options Glossary

pH: pH is a measurement of the acidity of your water. Sensors are available in standard and gold tipped for salt water pools.

ORP: Oxidation Reduction Potential measures chlorine's ability to oxidize contaminants in your pool water. Sensors are available in standard and gold tipped for salt water pools.

PPM: Parts Per Million. Some sensors (such as Chemtrol) measure PPM rather than ORP. Probes are available for Free Chlorine, Total Chlorine, Bromine, and more. Precision of PPM probes vary. For example, a 0-010 PPM probe measures between 0 and 10 parts per million. A 0-200 PPM probes measures between 0 and 200 parts per million. As with pH and ORP, gold tipped is available for salt water pools.

Cable Length: A chemical controller and flow cell are typically installed in close proximity. As such, a cable length of 2 feet is usually sufficient. If your flow cell is not installed next to your controller, cable lengths of up to 10 feet are available.

High Pressure pH or ORP: Systems requiring the use of high-pressure probes are rare. Use one only if the manufacturer of your chemical control system specifies the use of high-pressure probes.

Cleaning Your Chemical Probes

Sensors should be clean and free from oil, chemical deposits, and contamination to perform at optimal levels. Depending on your bather load and characteristics specific to your facility, probes may need to be cleaned on a monthly or even weekly basis. Failure to do so could result in slow sensor response, a frequent need to recalibrate sensors, and inconsistent readings.

You Will Need

  1. Soft toothbrush
  2. Mild degreaser such as Joy or other non-acid based household dish detergent
  3. Regular toothpaste
  4. Fresh water
  5. Teflon tape
  6. Clean container with water to keep sensor tip wet while cleaning

Cleaning Steps

  1. Turn off your controller, pH feeder, and your sanitizer feeder.
  2. Close flow cell valves. If the probes are installed in-line and cannot be isolated, turn off the main circulation pump.
  3. Remove sensors from the flow cell. Sensors should be unscrewed by hand. Disconnect the connectors from the controller.
  4. Carefully place your sensor into your clean container to ensure that the tip remains wet.
  5. Remove old Teflon tape and discard.
  6. Use a soft toothbrush with regular toothpaste to gently scrub the white ring and the tips of the sensors located at the bottom of the probe.
  7. If you notice oil and/or calcium buildup gently scrub with a household dishwashing detergent.
  8. Rinse with the clean fresh water in your container.
  9. Replace Teflon tape.
  10. Reinstall the sensors by hand tightening only. Only turn the probes enough to stop leaking.
  11. Reconnect to the connectors on the controller.
  12. Manually test and balance your water. Your water chemistry should be at the optimal balance for adherence with your local health department requirements.
  13. Open the flow cell valves or turn the circulation pump back on.
  14. Perform a hard reset at the controller. (See Manual for details.)
  15. Give the ORP probe a minimum of 20-30 minutes to acquire its proper reading and make the displayed reading at the controller your new ORP set point.
  16. Check the pH reading at the controller against your manual test kit reading. If the two differ, you must calibrate your controller to read the same as your pH test kit. After recalibrating your pH, set your pH set point to the current displayed reading.
  17. Turn on your pH feeder and your sanitizer feeder.

Additional Tips

  1. Never allow a pH or ORP sensor to dry completely. Drying will damage the reference junction and void the sensor warranty.
  2. If storing sensors for an extended period, store sensors in the soaking caps provided with the original storage solution or clean water or distilled water. Take care to protect from freezing temperatures when not in use.
  3. If storage containers have been misplaced, store sensors individually in small glass or plastic containers with clean water, ensuring that sensor tips are covered.
{{block type="core/template" template="chemical_probes/chemical_probes.phtml"}}
Top
Shopper Approved
Secured by Trustwave